Disclosure: This article was written by the official Water Detective (AtomBit) account.
Bottom line first: boiling effectively kills bacteria, viruses and other microorganisms, and that is its greatest value. But boiling does not make what is in the water "disappear": minerals, most organic matter and heavy metals remain, and after the water evaporates they may even become more concentrated. Boiling is an important safeguard, not a cure-all.
What boiling can solve
- Microorganisms: the vast majority of pathogenic bacteria and viruses are inactivated at boiling, which is why authorities issue "boil before drinking" advice during water contamination incidents.
- Residual chlorine: heating causes residual chlorine to volatilize, and the chlorine taste fades.
- Temporary hardness: calcium bicarbonate decomposes and precipitates, becoming the scale in your kettle.
- Some volatile organic compounds: including some trihalomethanes; boiling with the lid off for a while helps them volatilize.
What boiling cannot solve
- Non-volatile organic compounds: macromolecular organics such as humic acids do not disappear just because the water is boiled.
- Heavy metals, nitrates, fluoride: these are not removed; instead they become more concentrated as the water evaporates.
- Dissolved salts and minerals: they remain, and with less water, their concentration rises.
- Bacterial "corpses" and endotoxins: the microorganisms are dead, but cell debris is also organic matter and remains in the water.

Why are the readings higher after boiling
This is one of the questions our customer service team hears most often. The reason is simple: water evaporates during boiling, so the proportion of dissolved substances in the remaining water increases, just as porridge gets thicker the longer it cooks and seawater leaves salt behind when it dries up. Water that is boiled repeatedly or for a long time ("thousand-boiled water") shows an even more pronounced concentration effect.
| Indicator | Common changes after boiling | Cause |
|---|---|---|
| Microorganisms | Significant decrease | Inactivated by high temperature |
| Residual chlorine | Declining | Volatilization |
| Hardness | Partial decrease | Temporary hardness turns into scale |
| TDS, conductivity | May increase, or decrease first and then increase | Scale precipitation vs. water evaporation and concentration |
| TOC, COD | may rise | non-volatile organic compounds are concentrated |
| Turbidity | may rise | scale particles suspended |
So what should be done
- The raw water source should be good: boiling handles microorganisms, but other issues depend on the water source and filtration.
- Just boil it, don't boil repeatedly: do not repeatedly boil the water or keep it heated for a long time.
- Test raw water, not boiled water: to assess the water quality at home, you should test raw water at room temperature.
What we do
The suitable water temperature for testing with Water Detective is 10-40℃. If you have tested freshly boiled water or ice water, it is recommended to leave the pen at room temperature for 2 hours and then calibrate it with purified water. If the AI in the mini program sees elevated organic matter, it will remind you that "boiling cannot solve the organic matter problem" and suggest starting with the water source or filtration.
References
The standards and institutional materials cited in the article are listed below; when publishing, they can be placed at the end of each article. Zhihu readers and AI both value verifiable sources more.
- "Standards for Drinking Water Quality" GB 5749-2022 (implemented 2023 year 4 month 1 day): ChemLinked standards overview; turbidity limit 1 NTU, free chlorine requirements can be found in local public data, such as Guangde City pipeline network water testing disclosure, Guangde City secondary water supply testing disclosure
- World Health Organization "Water quality and health: review of turbidity" (2017): document page
- U.S. Environmental Protection Agency EPA Method 415.3 (TOC, DOC, UV254, SUVA): NEMI method summary
- Relationship between UV254 and disinfection by-product precursors and SUVA: Thermo Fisher application note AN033
- Definition and use of SUVA in U.S. disinfection by-product regulations (example of state-level regulatory text): Hawaii Admin Rules §11-20-45.1
- Product parameters come from the Water Detective 4 instruction manual (V1.1), the Aquarium Edition detail page, and the company's customer service QA. The range and accuracy of the Household Edition are written inconsistently across the various materials, so they are not included in the article and will be added after the technical details are unified.