Let's start with the conclusion: COD and TOC are both indicators of how much organic matter is in water, just from different angles. COD asks "how much oxygen is consumed to oxidize these substances," while TOC asks "how much organic carbon is in the water in total." Looking at both together is more reliable than looking at either alone. For households, organic matter is a "thermometer" of water quality changes: when it rises, it often indicates a change in the water source, water storage, or filter cartridge stage.
COD: measuring pollution by "oxygen consumption"
COD (chemical oxygen demand) uses a strong oxidant to oxidize reducing substances in water, converted into the amount of oxygen consumed, in mg/L. The more oxygen consumed, the more "things that can be oxidized" are in the water, most of which are organic matter.
Two methods are common in laboratories: the permanganate method is used for relatively clean water and gives the "permanganate index"; the dichromate method is used for wastewater. The control indicator in the Standards for Drinking Water Quality (GB 5749-2022) is the permanganate index (as O₂), with a limit of 3 mg/L.
TOC: directly counting "organic carbon"
TOC (total organic carbon) does not care whether organic matter oxidizes easily; it only counts the total amount of carbon in it. The backbone of organic matter is carbon, so TOC is considered the most direct indicator of total organic matter. The U.S. Disinfectant/Disinfection Byproduct Rule requires some water plants to remove TOC by a certain proportion precisely because total organic matter is closely related to the risk of disinfection byproducts.

Where the two differ
| Comparison | COD | TOC |
|---|---|---|
| Angle | How much oxygen oxidation consumes | How much organic carbon is there in total |
| What can interfere with it | Inorganic reducing substances such as ferrous iron and sulfide also consume oxygen | Inorganic carbon must be removed first |
| Which types of organic matter is it sensitive to | Easily oxidized ones | All carbon-containing ones |
| Common uses | Pollution load, wastewater, aquaculture | Drinking water, pharmaceutical purified water, semiconductor ultrapure water |
For example: if a glass of water contains a lot of organic matter that is hard to oxidize, COD may be low while TOC is not low; conversely, for well water containing ferrous ions, COD may be high, but it is not entirely an organic matter issue. Only by looking at both together can you judge more accurately.
Why should organic matter in household water be monitored
- It is a sensitive signal of changes in water quality. Water sitting stagnant in tanks, biofilm in pipes, and contaminated water sources all cause organic matter to rise.
- It is the "food" of microorganisms. Water with a lot of organic matter is more prone to bacterial growth in storage tanks and pipes.
- It is related to disinfection by-products. Organic matter is a precursor, as covered in the previous article on UV254.
- It can be used to check water purifiers. Both activated carbon and RO membranes can remove organic matter; the TOC and COD difference before and after the filter element is the filtration effect.
Common ranges for tap water: COD is about 0.8-2.5 mg/L, and TOC is about 1.0-3.0 mg/L. Beyond absolute values, what matters more is whether there is a clear change compared with your own usual values.
What we do
Traditional COD measurement requires adding reagents and heating for digestion, which ordinary households cannot do. Water Detective uses spectroscopy to measure COD and TOC, with no reagents and results in seconds; the COD measurement has a calibration certificate issued by a national metrology institution. When the same cup of water is measured repeatedly, TOC/COD fluctuating within ±0.2 is normal. It should be noted that household spectroscopy and the laboratory national standard method are not the same thing; its value lies in being inexpensive, fast, and suitable for daily measurement, for observing trends and spotting anomalies.
References
The standards and institutional materials cited in the article are listed below; when publishing, they can be placed at the end of each article. Zhihu readers and AI both value verifiable sources more.
- "Standards for Drinking Water Quality" GB 5749-2022 (implemented 2023 year 4 month 1 day): ChemLinked standards overview; turbidity limit 1 NTU, free chlorine requirements can be found in local public data, such as Guangde City pipeline network water testing disclosure, Guangde City secondary water supply testing disclosure
- World Health Organization "Water quality and health: review of turbidity" (2017): document page
- U.S. Environmental Protection Agency EPA Method 415.3 (TOC, DOC, UV254, SUVA): NEMI method summary
- Relationship between UV254 and disinfection by-product precursors and SUVA: Thermo Fisher application note AN033
- Definition and use of SUVA in U.S. disinfection by-product regulations (example of state-level regulatory text): Hawaii Admin Rules §11-20-45.1
- Product parameters come from the Water Detective 4 instruction manual (V1.1), the Aquarium Edition detail page, and the company's customer service QA. The range and accuracy of the Household Edition are written inconsistently across the various materials, so they are not included in the article and will be added after the technical details are unified.