Why a joint review is needed
In smart water appliances, conductivity/TDS detection is not something that "works stably as soon as a chip and probe are connected." It spans the chip, probe, mainboard, wiring harness, structure, water path, firmware, App and after-sales service. A seemingly minor bubble retention, an overly long harness or a structural sealing issue can all cause measurement jumps or after-sales failures. The goal of the joint review is to elevate "measurable at a single point" to "reliable as a whole machine, manufacturable and maintainable."
This article uses AtomBit's interface ASICs for smart water appliances BA121, BA234 and the 3/8-inch digital probe as examples to present an executable review method. This article also applies to project reviews when OEM/ODM customers introduce AtomBit chips and probes, helping avoid project delays caused by structural changes, harness lengthening or unclear firmware protocols. The boundary is clear: these devices are used for water-quality trends, filter management and anomaly alerts within consumer-grade equipment, and are not equivalent to laboratory metrological analysis or regulatory compliance testing.
1. First distinguish two types of review objects: chips and probes
1.1 BA121: minimum-system ASIC
BA121 is a single-channel conductivity and water-temperature detection ASIC with a built-in conductivity conversion algorithm, automatic temperature correction, single-channel detection and bipolar probe drive, requiring few external components. It suits products with tight onboard space and a desire to reduce analog debugging effort, such as small smart cups and pet water dispensers. During review, focus on: whether temperature compensation is consistent with the system calibration strategy; the polarity requirements of bipolar drive for the probe; and sensitivity to power-supply ripple and external noise with minimal external components.
1.2 BA234: two-probe interface ASIC with UART output
BA234 is a single-channel two-probe measurement ASIC with automatic NTC temperature compensation, bipolar pulse excitation, simple control commands and UART digital output at 9600 bps. Firmware does not need to perform complex analog conversion, making it suitable for projects where the water purifier/water dispenser mainboard MCU has few ports and fast integration is desired. During review, focus on: whether the UART data update cycle and command response time meet the product's real-time display/filter judgment needs; whether the two-probe layout requires pairing; and the anti-interference capability of 9600 bps over long harnesses.
1.3 3/8-inch digital probe
This probe supports EC, TDS and salinity, with titanium, gold or platinum electrode options, corrosion-resistant solid molding, a built-in high-precision temperature sensor, food-contact-grade materials and 3/8-inch quick connection. It suits water purifiers, water dispensers, coffee machines and similar products where water-path integration is convenient. During review, focus on: selecting the electrode material according to the chemical characteristics of raw water/filtered water; the sealing level and cleaning convenience at the quick connection; and whether the built-in temperature sensor's response time meets display refresh requirements.
1.4 组合选型决策表
| 项目条件 | 优先考虑 | Cause |
|---|---|---|
| 极紧凑、模拟前端自行设计 | BA121 | 外部元件少,简化模拟链路 |
| 希望数字输出、降低固件复杂度 | BA234 | UART 9600 bps,命令简单 |
| 需要快接、食品接触级探头 | 3/8-inch 数字探头 | 支持 EC/TDS/盐度,温度内置 |
| 多种水质或盐度扩展 | BA234 + digital probe | Digital links reduce wiring-harness effects |
2. Hardware review: not just reading the datasheet
2.1 Power supply and decoupling
Conductivity measurement is essentially a tiny-current measurement under high-frequency/bipolar excitation. The review must confirm whether the ASIC supply rail is clean and the decoupling capacitors are close to the power pins, and whether the measurement jumps when motors, solenoid valves or pumps start and stop.
2.2 Probe excitation and analog routing
For BA121, the probe excitation and sampling traces should be kept away from switching power supplies and Wi-Fi/BLE RF areas; the wiring harness is recommended to be shielded or twisted pair, and as short as the structure allows. If long cables are unavoidable, prefer the BA234 digital output to reduce the risk of long-distance transmission of small analog signals.
2.3 ESD and connectors
Smart water appliances usually involve user contact and water tank removal/installation. The review must confirm that the probe interface has ESD protection, and that connector plating and mating durability meet the requirements of repeated after-sales disassembly and assembly.
2.4 Temperature compensation chain
BA121 automatic temperature correction and BA234 automatic NTC compensation, but NTC connections, reference resistor tolerance, harness resistance and other factors all introduce deviations. The review should test at different temperature points to confirm that the display does not jump.
2.5 Ground loops and common-mode interference
If the probe housing comes into contact with a metal water path, confirm whether this causes a ground loop; isolate or use single-point grounding if necessary. In the complete system, the water path may carry voltage or induced voltage, so common-mode testing should be used to confirm that measurement is unaffected.
3. Structure and water path review: the hidden key to measurement stability
3.1 Probe installation position
The conductivity/TDS electrode must be fully immersed, avoiding bubble adhesion. The review should check: whether the lowest water level in the tank covers the electrode; whether the probe in the circulation water path is in a full-pipe section; whether high-speed water flow directly impacts the electrode surface and causes reading fluctuations.
3.2 Sealing and food contact
For the quick-connect structure, consider the O-ring material, compression amount, and whether leakage occurs after long-term hot-cold cycling. The probe is made of food-contact-grade material, but adapters, wiring harness seals, adhesives, etc. must also meet the complete system's food-contact and water path safety requirements.
3.3 Manufacturability and maintainability
Whether the wiring harness is easy to assemble automatically; whether the probe installation direction is mistake-proof; whether after-sales probe replacement can be done without disassembling the complete system. The review should require structure, hardware, and after-sales teams to jointly confirm the disassembly and assembly path.
3.4 Shaking, tilting and refilling
For mobile water cups and pet water dispensers, simulate tilting, water shortage, and refilling with cold water, and observe the reading stabilization time. The probe should not show severe jumps at low water level or in a half-immersed state; otherwise, adjust the installation angle or add a water-blocking structure.
4. Joint review of firmware, App and after-sales: turning data into useful decisions
4.1 Data filtering and thresholds
Raw TDS/EC values show short-term fluctuations caused by pump startup, air bubbles and temperature changes. The firmware should apply a moving average or median filter, but filtering too heavily will mask real changes. The review must define the filter life judgment as trend logic, not a single-point jump.
4.2 Status and error codes
The chip and probe should report abnormal states: probe open circuit, short circuit, temperature out of range, invalid data. The App must not display error values as normal TDS; it should prompt "Abnormal detection, please check the probe."

4.3 Display and filter management boundaries
TDS values displayed to users should be labeled as "reference value/trend value" to avoid direct comparison with laboratory testing. Filter replacement reminders may be based on cumulative water usage or conductivity trends, but must not claim to achieve medical or laboratory-grade accuracy.
4.4 After-sales calibration and failure determination
After-sales needs to prepare conductivity standard solutions of known value or reference units to determine whether a probe has failed. The joint review should define the after-sales calibration process, allowable deviation and scrapping criteria.
4.5 Parameterized design
OEM/ODM projects often involve multiple models; the firmware should make calibration coefficients, filter depth and filter thresholds configurable parameters, avoiding recompilation for each model and reducing batch maintenance risk.
5. Joint review implementation steps
It is recommended to proceed in four stages:
5.1 Prototype stage review
Objective: confirm the functionality of the measurement chain. Prepare a transparent water path or quick-connect fixture and observe bubbles; verify the chip output with a solution of known conductivity; record readings at different temperatures. Review questions:
- Is the probe fully immersed?
- Are the excitation and sampling lines subject to interference?
- Are the readings monotonic after temperature compensation?
- Is data frame parsing stable?
5.2 Engineering prototype stage review
Objective: confirm full-device integration. Install the probe in the actual water tank/water path and test the lowest/highest water levels, pump start/stop, device vibration and transport jolts. Review questions:
- Are readings normal at the lowest liquid level?
- Do readings show obvious jumps at the moment the pump starts?
- Does bending the wiring harness affect measurement?
- Is the seal leak-free after long-term immersion?
5.3 Small-batch trial production review
Objective: confirm manufacturability consistency. Sample multiple units and compare output consistency on the same water sample. Review questions:
- Are combinations of different probe batches and chip batches consistent?
- Does assembly position deviation cause reading differences?
- Can performance be restored after after-sales disassembly and reassembly?
- Are there error codes covering data upload/display?
5.4 Mass production stage review
Objective: confirm long-term reliability. Sample and conduct temperature cycling, humidity and lifetime tests. Review questions:
- Does temperature compensation drift after temperature cycling?
- Is there visible scaling or corrosion on the electrode surface?
- Are user-perceivable fluctuations within an acceptable range?
Review outputs should at least include: an issue list, decision records, verification reports and residual risks.
6. Verification approach: from laboratory bench to complete-device scenarios
- Functional calibration: use standard conductivity solutions with known values (for example, common TDS/conductivity calibration solutions) for two-point or three-point fitting, and keep the error within the range allowed by the product definition.
- Temperature test: 5°C, 25°C, 45°C or the product's actual water temperature range; confirm that the reading trend after automatic temperature compensation conforms to the pattern of conductivity change.
- Water flow impact test: place the probe under different flow rates and observe fluctuations in the readings.
- Bubble interference test: intentionally introduce bubbles into a transparent water path and confirm that filtering and abnormal states can be identified.
- Long-term immersion and intermittent drying: simulate a water tank that has water for long periods and occasionally runs dry, and check the electrodes and seals.
- Complete-device EMC: when the motor, pump and wireless module operate simultaneously, check UART communication and data stability.
- Compare trends with a portable Water Detective: in the same sequence of water sample changes, compare the complete-device trend with the trend of the portable device and confirm that the direction is consistent, while avoiding any requirement for absolute equality.
7. Limitations and boundaries
- The products covered in this article are used for internal detection in consumer-grade smart water appliance devices, providing trend indication, filter management and abnormal alerts; they do not replace laboratory instruments or regulatory testing.
- Conductivity/TDS readings are affected by factors such as temperature, bubbles, electrode contamination, water flow conditions and raw water composition.
- The filter-life algorithm is a multi-parameter model; TDS/EC is only one input and cannot be used alone to determine filter failure.
- If optical COD/TOC/UV254 is used for built-in detection in household devices, it should likewise be positioned as a trend and screening tool, requiring more complex optical paths, anti-fouling measures and calibration logic; this article does not elaborate further.
8. Frequently Asked Questions (FAQ)
Q1: How to choose between BA121 and BA234?
If the structure is extremely compact, the analog front end is self-designed, and minimal external components are desired, prioritize BA121; if simpler firmware, a slightly longer harness, and tight MCU resources are preferred, prioritize BA234, whose UART digital output can reduce the burden of analog signal routing.
Q2: Can 3/8-inch digital probes be directly submerged in a water tank?
The actual installation method needs to be evaluated. The probe uses food-contact-grade materials and a corrosion-resistant molded seal, but prolonged exposure to high-temperature steam, strong ultraviolet light, or sharp mechanical impact should be avoided; during installation, ensure the electrodes are fully immersed and avoid dry burning or partial immersion.
Q3: How often does the TDS displayed value need calibration?
For consumer products, frequent user calibration is not recommended. During mass production, initial consistency is determined through standard solutions and temperature verification; if drift is suspected after sale, a known-conductivity standard solution can be used to check trends. The calibration interval should be defined in conjunction with product lifespan, water quality, and electrode material, and should not be promoted as "maintenance-free."
Q4: Can the filter life reminder be determined directly using TDS values?
Relying only on a single TDS value is not recommended. TDS/EC changes are affected by factors such as raw water fluctuations and temperature, and can be used for trend analysis, but filter life should be determined jointly by cumulative water usage, usage time, flow rate, and conductivity trends, and the App should state that this is an estimated reminder, not a laboratory test.
Conclusion
The essence of a joint review for a water-quality chip project is aligning the chip's "capability boundaries" with the product's "real water path, real users, and real after-sales." BA121/BA234 provide integration-friendly conductivity/temperature detection capabilities, and 3/8-inch digital probes offer quick-connect and food-contact options, but overall measurement reliability still depends on the coordination of hardware layout, structural water-path design, firmware filtering, and after-sales calibration. Only by moving these professional reviews forward to the prototype stage can display jumps, after-sales misjudgments, and user complaints after mass production be avoided.