Intended users and decision questions
This article is intended for households with newborns or postpartum women, as well as for brands and integrators that provide these households with products such as water purifiers, water dispensers, and water storage buckets. It uses AtomBit Water Detective ATBKEEP80179D1CE651X0000END (hereinafter referred to as ATBKEEP80179D1CE651X0001END) as a screening tool, covering nine indicators: TOC, COD, ATBKEEP80179D1CE651X0002END, turbidity, TDS, conductivity, salinity, hardness, and temperature. ATBKEEP80179D1CE651X0001END is a personal/household portable water quality test pen, suitable for on-site household screening and comparison of water purifier performance, but ATBKEEP80179D1CE651X0003END cannot replace laboratory analysis ATBKEEP80179D1CE651X0003END. The following steps are intended to help users establish a repeatable water storage hygiene monitoring process and distinguish between "screening abnormality" and "confirmed contamination."
This article is intended for households with newborns or postpartum women, as well as for brands and integrators that provide these households with products such as water purifiers, water dispensers, and water storage buckets. It uses AtomBit Water Detective 4 (hereinafter referred to as WD4) as a screening tool, covering nine indicators: TOC, COD, UV254, turbidity, TDS, conductivity, salinity, hardness, and temperature. WD4 is a personal/household portable water quality test pen, suitable for on-site household screening and comparison of water purifier performance, but cannot replace laboratory analysis . The following steps are intended to help users establish a repeatable water storage hygiene monitoring process and distinguish between "screening abnormality" and "confirmed contamination."
Key decision questions:
- Which indicators are measured using ATBKEEP3ABBF10F94EBX0000END? Within what range can readings be considered "normal" or "trend-stable"?
- Which indicators are measured using WD4? Within what range can readings be considered "normal" or "trend-stable"?
- How should data be recorded to track changes in water storage hygiene?
- Applicable water samples and water storage scenarios
Water samples, equipment and scenario boundaries
Water flowing directly from a tap
WD4 is suitable for domestic water, water purifier output, bottled water (after opening), cooled boiled water, water in storage containers, etc. For postpartum households, typical testing points include:
- Output of water purifiers or water dispensers.
- Water purifier (ultrafiltration/reverse osmosis/activated carbon) output water
- Boiled water, cooled after boiling
- Water in storage containers (food-grade plastic buckets, glass bottles, stainless steel kettles)
- Water for humidifiers (if a water storage format is used)
Not applicable: industrial wastewater, municipal sewage, river water, well water (unless properly pre-treated and explicitly for screening only), medical water. This guide does not cover the above scenarios.
WD4 What it can do and what it cannot do
WD4 measures nine indicators, of which:
- TOC (Total Organic Carbon): reflects the total amount of organic matter in water; can be used to compare trends in organic pollution before and after a water purifier or before and after storage. A rising reading may indicate the introduction of organic matter (such as container leaching, biofilm), but cannot identify specific organic compounds.
- COD (Chemical Oxygen Demand): similar to TOC, reflects the total amount of oxidizable substances; a screening indicator.
- UV254: reflects organic matter with unsaturated bonds or aromatic structures, such as some humic substances and certain industrial pollutants, but is likewise non-specific.
- Turbidity: indicates suspended particles in water, such as rust, sediment, and colloids. High turbidity may affect disinfection efficacy (if chlorination is used) and indicate filtration problems, but does not mean microorganisms are present.
- TDS (Total Dissolved Solids): total dissolved inorganic salts, affecting taste. Usually converted from conductivity.
- Conductivity (EC): a direct measurement of ion concentration in water; high conductivity may mean high mineral content, but it does not mean unsafe.
- Salinity: salt content estimated from conductivity.
- Hardness: calcium and magnesium ion content, which affects scale and taste.
- Temperature: affects compensation of other parameters and the microbial growth rate.
Important limitation: WD4 cannot detect bacteria, viruses, parasites, lead, arsenic, nitrates, nitrites, pesticides, dissolved oxygen, ammonia nitrogen, etc. Any health judgment involving these risks (such as "this water is safe to drink") must be completed by a qualified laboratory using local standard methods. WD4 provides only screening, comparison and trend observation, and should not be used as proof of drinking safety, pet health or aquaculture compliance.
Preparation before measurement and device calibration
- Make sure the WD4 battery is sufficiently charged and the probe is clean.
- Perform zero-point or standard-solution calibration according to the instructions (if applicable). Check the zero point with pure water or deionized water at least once a month.
- Before measurement, rinse the probe 2–3 times with the water sample to be tested to avoid cross-contamination.
- The water temperature should be close to room temperature (20–25°C). If the deviation is large, record the temperature and pay attention to compensation.
Reproducible sampling and measurement steps
The following steps are suitable for home users and non-professional operators. It is recommended to keep the sampling time, location and container fixed to improve data comparability.
Step 1: Select and prepare the water storage container
- Material: Prefer food-grade polycarbonate (PC), polypropylene (PP), high-density polyethylene (HDPE) or stainless steel (304/316). Avoid old plastics containing bisphenol A (BPA) or non-food-grade containers.
- Cleaning: First clean new containers with neutral detergent, then rinse with plenty of tap water, and finally rinse with pure water/cooled boiled water. If disinfection is needed, diluted food-grade hydrogen peroxide or a dedicated container disinfectant may be used, but it must be thoroughly rinsed to avoid residue affecting TOC/COD readings.
- Before first use: Fill with water and let stand for 24 hours, then pour out and rinse again to reduce leachables.
Step 2: Sampling
- Determine the sampling point: such as a tap water faucet, water purifier outlet, or inside a water storage container.
- Before sampling, run the water for at least 30 seconds (if using a water purifier, rinse according to the instructions).
- Use a clean, dry container (such as the sample cup supplied with WD4 or a disposable food-grade cup) to collect about 100 mL of water sample.
- Measure immediately to avoid prolonged exposure to air causing CO₂ absorption or microbial growth.
Step 3: Measurement operation
- Turn on WD4 and select multi-parameter measurement mode.
- Fully immerse the probe in the water sample, stir gently to remove air bubbles, and wait for the reading to stabilize (usually 15–30 seconds).
- Record the temperature, TDS, conductivity, turbidity, TOC, COD, UV254, hardness and salinity readings.
- Repeat the measurement at each sampling point 2 times and take the average. If the difference between two measurements exceeds 10%, check whether the probe is contaminated, whether the water sample is uniform, and whether the temperature has changed.
- After measurement, rinse the probe with pure water, wipe it dry and store it.
Step 4: Data recording
It is recommended to use a spreadsheet or a paper record sheet containing the following fields: date, time, sampling point, container type, water temperature, readings for each parameter, operator, and remarks (such as whether the filter was just replaced, whether the water was boiled, and whether the container is clean).
How to interpret results and common interferences
Establish a baseline
Before starting water storage, first measure the source water (tap water or water purifier outlet) as a baseline. After storage, measure regularly to observe the trend of change. normal fluctuation range : TDS/conductivity is usually stable (within ±10%); if there is no evaporative concentration in the stored water, it should not rise significantly; turbidity should remain low (<1 NTU as visually appropriate, but not an absolute limit); TOC/COD/UV254 should be close to the baseline if the storage container is clean and well sealed; a slight increase may come from trace leaching from the container, but continuous increases require attention.

Abnormal patterns and possible causes
| Reading change | Possible cause | Recommended action |
|---|---|---|
| TDS/conductivity increase >20% | Evaporative concentration, container leaching, cross-contamination | Check whether the container is clean and sealed; re-measure the source water to confirm |
| Turbidity elevated | Introduction of particulate matter, microbial growth (possibly accompanying), filter failure | Stop drinking; check the filtration system; if high turbidity persists, send a sample to a laboratory for microbiological testing |
| TOC/COD/UV254 significantly elevated | Organic contamination, such as detergent residue, leaching from container materials, biofilm | Thoroughly clean the container; change the water source; retest after multiple rinses |
| Hardness increased | Water source change or evaporative concentration | Does not affect safety, but may affect taste and cause equipment scaling |
| Abnormal temperature | High storage ambient temperature, which may promote microbial growth | Store water in a cool place and avoid exceeding 25°C |
Note: The above patterns are only screening hints; they cannot determine the specific contaminant. For example, elevated TOC may be harmless natural organic matter or detergent residue; on-site conditions must be considered and laboratory confirmation should be taken into account.
Common measurement interferences
- Bubbles : Bubbles attached to the probe surface can cause reading drift, especially affecting turbidity and optical parameters. Stir, then let it stand briefly before taking a reading.
- Temperature : Temperature affects conductivity and optical measurements; WD4 has internal temperature compensation, but errors increase at extreme temperatures. Measure at 20–25°C whenever possible.
- Probe contamination : Oil, scale and biofilm can interfere with the optical window and electrodes. Clean regularly with a soft cloth and pure water, and use a dedicated cleaning solution if necessary.
- Sample cup contamination : Use disposable or thoroughly cleaned cups to avoid detergent residue.
- Strong light or ambient light : For optical measurements, avoid direct sunlight or strong light and measure indoors.
- Uneven water sample : If the water contains sediment or suspended matter, gently shake to mix and measure immediately, but avoid vigorous shaking that creates bubbles.
When to retest, stop using, or send to a laboratory
Retest plan
- Routine : Retest the storage container once every 3 days for two weeks, then once a week.
- Event-triggered : Retest immediately after changing the water source, cleaning the container, replacing the water purifier filter, or suspecting contamination (such as a power outage, flood, or odor).
- Retest method : Compare with the baseline. If readings return to the normal range and are stable, continue using; if abnormalities persist, take the actions below.
Conditions for stopping use (stop drinking immediately and switch to another safe water source)
- The water has an odor, abnormal color, turbidity, sediment, or visible microorganisms (such as floc).
- WD4 turbidity >5 NTU (screening threshold only, not a regulatory limit, but discontinuation and investigation are recommended).
- TOC or COD readings elevated above baseline by more than 50% and sustained across two consecutive measurements.
- Family members (especially postpartum women or infants) develop symptoms possibly related to drinking water, such as diarrhea or vomiting.
- The water storage container is damaged, contaminated, or has been stored for more than 7 days without replacement.
Situations requiring laboratory confirmation
When any of the following situations occurs, must send the water sample to a qualified laboratory and test it according to local standard methods:
- Microbial contamination is suspected (e.g., the water source is contaminated by feces, after flooding, or a sewage leak is nearby): test for total coliforms, Escherichia coli, fecal streptococci, etc.
- Heavy metals are suspected (old pipes may contain lead): test for lead, copper, etc.
- Living in an agricultural area or using well water: test for nitrates, nitrites, and pesticides.
- The water storage container may release specific chemicals (e.g., BPA, phthalates): specialized testing is required.
- Abnormal readings that cannot be explained by WD4 persist.
laboratory sampling requirements : use a sterile container (provided by the laboratory or purchased), collect the sample as instructed, and usually deliver it to the laboratory within 24 hours, keeping it refrigerated.
记录表/行动清单
Daily record sheet (example)
| Date | Sampling point | Water temperature (°C) | TDS (ppm) | Conductivity (µS/cm) | Turbidity (NTU) | TOC(ppb) | COD (ppm) | UV254 | Hardness (ppm) | Salinity (ppt) | Remarks |
|---|---|---|---|---|---|---|---|---|---|---|---|
| 2025-01-01 | Water purifier outlet | 22 | 45 | 90 | 0.3 | 120 | 0.5 | 0.010 | 30 | 0.02 | Baseline |
Action checklist
- [ ] Confirm the water storage container is made of food-grade material and thoroughly clean it before first use.
- [ ] Establish a baseline for the source water and record all parameters.
- [ ] Retest every 3 days for two consecutive weeks, then once a week.
- [ ] Rinse the probe before each measurement, and clean and store it after measurement.
- [ ] If readings are abnormal, check the container, water source and filter, and retest.
- [ ] If any unusual odor, unusual color or health symptoms occur, stop using the water immediately and send it to a laboratory for testing.
- [ ] Keep records for at least 6 months for traceability.
FAQ
Q1: Can the Water Detective 4 test for bacteria? No. WD4 It does not include a microbiological testing function. Bacteria, viruses, parasites and the like require laboratory culture or molecular methods for confirmation. Increased turbidity may indicate microbial growth, but it is not direct evidence.
Q2: Is water with low TDS necessarily safe? No. TDS only reflects the total amount of dissolved solids; low TDS does not mean there are no microorganisms or trace toxic substances. For example, reverse osmosis product water has very low TDS, but it may still be unsafe if the piping is contaminated.
Q3: If TOC rises after water has been stored for several days, does that mean the water has gone bad? Not necessarily. A rise in TOC may come from trace leaching from the container or dust falling in from the air, and should be judged together with other indicators and storage conditions. If turbidity also rises or an odor appears, it is advisable to stop using the water and have it tested.
Q4: Which indicators need to be measured after boiled water has cooled? Boiling mainly kills microorganisms but cannot remove heavy metals, nitrates and the like. After cooling, measuring TDS/conductivity, TOC and turbidity can confirm whether secondary contamination has occurred. Microbiological indicators still require a laboratory.
Q5: Can WD4 be used to check whether a water purifier filter cartridge needs to be replaced? Yes. By regularly measuring the purifier outlet water, when TDS (for reverse osmosis), turbidity, TOC and the like become noticeably worse than with a new cartridge, this suggests the cartridge may have failed. However, the specific replacement interval should still follow the manufacturer's recommendations.
References
The following sources support the general water quality concepts and screening methods in this article; for specific limits or requirements, please refer to the recommendations of your local authority or laboratory.
- World Health Organization. Guidelines for Drinking-water Quality, 4th edition incorporating the first addendum. Geneva: WHO; 2017. Link: https://www.who.int/publications/i/item/9789241549950
- United States Environmental Protection Agency. National Primary Drinking Water Regulations. Link: https://www.epa.gov/ground-water-and-drinking-water/national-primary-drinking-water-regulations (applies to the United States only)
- Centers for Disease Control and Prevention. Water Storage. Link: https://www.cdc.gov/healthywater/emergency/creating-storing-emergency-water-supply.html (provides recommendations for cleaning and replacing water storage containers)
- Household water storage hygiene guidelines issued by local health departments or water utilities (please check according to your region).
Regional applicability note: The operating steps and screening methods in this article apply to general household scenarios, but specific water quality standards, pollutant limits and laboratory test items should be implemented in accordance with the drinking water regulations of the country or region where you are located. WD4 readings cannot replace compliance testing. For households after childbirth, if there are concerns about water quality, it is advisable to give priority to boiled and cooled water or a certified water purifier, and to consult the local public health department.